Get power built for your most demanding gas compression applications. Every Cat® electric motor is tested at each stage of production to make sure it performs reliably under load and according to your process requirements. High operating efficiency and low operating costs come with low noise levels and no emissions. Cat electric motors for gas compression are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty.

Cat Specs
Photos
Downloads

Electric Motor Specifications

Voltage/Frequency
4000V & 4160V ± 10%/60 Hz
Type of EX-Protection
Class 1 Division 2 Group A,B,C,D T3 (NEC or CEC)
Shaft
8.5 in
Locked Rotor Torque
60%
Full Load Speed
894 rpm r/min
Locked Rotor Amps
540% Code E
Insulation
Class F
Maximum Ambient Temperature
104 °F
Duty
Continuous
Mounting Designation
F1 or F2
Rated Torque
20555 lb/ft
Service Factor
1.15 SF (1.0 VFD)
Electric Motor Type
Squirrel Cage Induction Motor
Connection of Stator Winding
Star
Temperature Rise
Class B at rated load
Full Load Current
458 Amps
Enclosure Type/Method of Cooling
WP-II
Maximum Altitude - Before Derate
3300 ft
No Load Current
137 Amps
Number of Poles
8 poles
Standards
NEMA MG1